      Details:

      It is used to transmit automatic control signal in the environment not only with exploding danger such as petroleum, chemical plant, power, gas project and mine but also with high demand on explosion proof performance. It is decentralized type instrument signal cable with the feature of low capacitance & low inductance & good shielding performance and interference proof performance, which is also named as Intrinsic safety type cable for DCS system. So, its performance of explosion-proof & safety is apparently higher compared with common computer control cable and cable for DSC.

      Executive standard: enterprise standard

      Performance for Usage

      1. AC rated voltage U0/U, 300/500V
      2. Max temperature of cable conductor for long term working is 70℃ for cable with PE insulation, 90℃ for cable with XLPE insulation and 70℃ for cable with free halogen, low smoke, flame retardant, polyolefin insulation.
      3. Min. environment temperature is -40℃ for fixed laying and -15℃ for non-fixed laying. Environment temperature for installing is no less than 0℃
      4. Bending radius allowed by cable is no less than 6 times that of cable OD for inarmored braided shielding cable and 12 times that of cable OD for copper tape shielding, armored cable.

      Basic Type and Description:


      Type

      Description

      IA-DJYPVP

      Intrinsic safety type cable for DCS system with Cu core, PE insulation, PVC sheath, copper wire braided general & individual shielding

      IA-DJYPVPR

      Intrinsic safety type soft cable for DCS system with Cu core, PE insulation, PVC sheath, copper wire braided general & individual shielding

      IA-DJYP3VP3

      Intrinsic safety type cable for DCS system with Cu core, PE insulation, PVC sheath, aluminum-plastic compound tape wrapped general & individual shielding

      IA-DJYP3VP3R

      Intrinsic safety type soft cable for DCS system with Cu core, PE insulation, PVC sheath, aluminum-plastic compound tape wrapped general & individual shielding

      IA-DJYP2VP2

      Intrinsic safety type cable for DCS system with Cu core, PE insulation, PVC sheath, copper-plastics compound tape wrapped general & individual shielding

      IA-DJYP2VP2R

      Intrinsic safety type soft cable DCS system with Cu core, PE insulation, PVC sheath, copper-plastic compound tape wrapped general & individual shielding

      IA-DJYJPVP

      Intrinsic safety type cable DCS system with Cu core, XLPE insulation, PVC sheath, copper wire braided general & individual shielding

      IA-DJYJPVPR

      Intrinsic safety type soft cable DCS system with Cu core, XLPE insulation, PVC sheath, copper wire braided general & individual shielding

      IA-DJYJP3VP3

      Intrinsic safety type cable for DSC system with Cu core, XLPE insulation, PVC sheath, aluminum-plastic compound tape wrapped general & individual shielding

      IA-DJYJP3VP3R

      Intrinsic safety type soft cable for DSC system with Cu core, XLPE insulation, PVC sheath, aluminum-plastic compound tape wrapped general & individual shielding

      IA-DJYJP2VP2

      Intrinsic safety type cable for DSC system with Cu core, XLPE insulation, PVC sheath, copper-plastic compound tape wrapped general & individual shielding

      IA-DJYJP2VP2R

      Intrinsic safety type soft cable for DSC system with Cu core, XLPE insulation, PVC sheath, aluminum-plastic compound tape wrapped general & individual shielding

      WDZ-IA-DJYPVP

      Intrinsic safety type soft cable for DSC system with Cu core, free halogen, low smoke, flame retardant, polyolefin insulation & sheath, copper wire braided general & individual shielding

      WDZ-IA-DJYPVPR

      Intrinsic safety type cable for DSC system with Cu core, free halogen, low smoke, flame retardant, polyolefin insulation & sheath, copper wire braided general & individual shielding

      WDZ-IA-DJYP3VP3

      Intrinsic safety type cable for DSC system with Cu core, free halogen, low smoke, flame retardant, polyolefin insulation & sheath, aluminum-plastic compound tape wrapped general & individual shielding

      WDZ-IA-DJYP3VP3R

      Intrinsic safety type soft cable for DSC system with Cu core, free halogen, low smoke, flame retardant, polyolefin insulation & sheath, aluminum-plastic compound tape wrapped general & individual shielding

      WDZ-IA-DJYP2VP2

      Intrinsic safety type cable for DSC system with Cu core, free halogen, low smoke, flame retardant, polyolefin insulation & sheath, copper-plastic compound tape wrapped general & individual shielding

      WDZ-IA-DJYP2VP2R

      Intrinsic safety type soft cable for DSC system with Cu core, free halogen, low smoke, flame retardant, polyolefin insulation & sheath, copper-plastic compound tape wrapped general & individual shielding


      ■ Main Technical Parameter

      1、DC resistance of conductor at 20℃



      nominal cross area section(mm2)

      Pieces of conductor/ diameter of single piece mm

      DC resistance of conductor at 20℃(Ω/km)

      A

      B

      R

      A、B

      R

      0.5

      1/0.8

      7/0.3

      16/0.2

      ≤36.0

      ≤39.0

      0. 75

      1/0.97

      7/0.37

      24/0.2

      ≤24.5

      ≤26.0

      1.0

      1/1.13

      7/0.43

      32/0.2

      ≤18.1

      ≤19.5

      1.5

      1/1.38

      7/0.52

      30/0.25

      ≤12.1

      ≤13.3

      2.5

      1/1.78

      7/0.68

      49/0.25

      ≤7.41

      ≤7.98

      2、Insulation resistance at 20℃



      performance item

      PVC insulation

      PE、XLPE insulation

      Insulation resistance at 20℃MΩ.KM

      ≥25

      ≥500

      3、Cable shall endure A.C. voltage test of 2000V under power frequency for 1min without puncture of insulation. And testing temperature is environment temperature.
      4、Working capacitance(1KHZ): core to core ≤90PF/m
      5、Distributing inductance(1KHZ)≤0.6μH/m
      6、Inductive voltage of electromagnetic interference(interference magnetic 400A/m)≤5mV
      7、Inductive voltage of electrostatic(static voltage 20KV)<1V
      8、Penetration stress of radiant field(stress of interference field is120dBμV ; frequency of interference field is 200MHZ)≤66dBμV


      Related Products :
      Duplex Conductor 600 V Secondary Type URD Cable - Aluminum Conductor
      Duplex Conductor 600 V Secondary Type URD Cable - Aluminum Conductor
      Computer Shielding Cable (Cable for DSC System)
      Computer Shielding Cable (Cable for DSC System)
      35KV or Lower Power Cable with XLPE Insulation
      35KV or Lower Power Cable with XLPE Insulation
      PVC Insulation & Sheath Power Cable of 0.6/1 kV or Lower
      PVC Insulation & Sheath Power Cable of 0.6/1 kV or Lower
      Mining Cable XLPE Insulation Flame Retardant 8.7/10kV or Lower
      Mining Cable XLPE Insulation Flame Retardant 8.7/10kV or Lower
      Metallic Shielding Power Cable
      Metallic Shielding Power Cable
      Mining Cable PVC Insulation Flame Retardant 3.6/6kV or Lower
      Mining Cable PVC Insulation Flame Retardant 3.6/6kV or Lower
      Power Flexible Cable for Telecommunication Power Supply
      Power Flexible Cable for Telecommunication Power Supply
      日本午夜天堂在线视频,自偷自拍的亚洲视频,2021精品国产自在现线看,2019久久久最新精品 亚太影院 柯西贝尔-游戏赚网
      1. <option id="etdgw"><pre id="etdgw"><dfn id="etdgw"></dfn></pre></option>
        <form id="etdgw"><center id="etdgw"><sup id="etdgw"></sup></center></form>